Bacteria Decomposition Test - Japanese Chinaware Examination Association

Test Procedure:

  1. Pipette 0.2mg of bacteria suspension on a test porcelain tile and a resin plate (50mm×50mm size)

  2. The test substrates are covered with a piece of polyethylene film.

  3.  Light of 500 LUX exposes the test glass for 24 hours. The test needs to be conducted in an environment where temperature is a constant 35.

  4. Count the number of survived bacteria

  5. In order to convert the number of bacteria in 1 ml, use SCDLP culture medium and measure the number on the test materials by a pour-plate culture way.

 

Bacteria decomposition test result on photocatalyst porcelain tile

Type of Bacteria Titanium Dioxide Immediately after illumination (number/ml) 24 Hours later (number/ml) % Killed
E. coli None 3.5 x 105 2.0 x 107

-

TO 3.5 x 105 < 10 > 99.9%
PTA 3.5 x 105 < 10 > 99.9%
MRSA None 1.9 x 105 9.0 x 104

-

TO 1.9 x 105 < 10 > 99.9%
PTA 1.9 x 105 < 10 > 99.9%